Heat transfer in a double pipe heat exchanger
Laminar Flow
1) Note down the Zero Error in digital Thermometers. Set the heater temperature.
2) Adjust the volumetric flow rate of water to 400 lph.
3) Adjust the flow rate of hot fluid in laminar region.
4) Measure the time taken to cross 10 cm mark using stopwatch and close valve.
5) Note the inlet-outlet hot-cold fluid temperature after steady state
6) Repeat the above steps to get 8 sets of readings by increasing the flow rate.
Turbulent Flow
1) Switch on the temperature indicator & controller.
2) Measure the inlet and outlet temperature for both the pipes for zero error.
3) Check the set point of the controller around 65 °C.
4) Start the hot fluid circulation pump.
5) Keep the flow rate of cold fluid constant at around 400 Lph
6) Adjust the flow rate of hot fluid (between 400 Lph to 900 Lph to maintain Re>10,000)
7) Once steady state is reached note down the inlet and outlet temperatures of hot and cold fluid.
8) Repeat the experiment for at least 6 different flow rates of hot fluid.